• Smart Integrated Flange Type Stable DN1400 Intelligent Electromagnetic Flow Meter MFE600E
  • Smart Integrated Flange Type Stable DN1400 Intelligent Electromagnetic Flow Meter MFE600E
  • Smart Integrated Flange Type Stable DN1400 Intelligent Electromagnetic Flow Meter MFE600E

Smart Integrated Flange Type Stable DN1400 Intelligent Electromagnetic Flow Meter MFE600E

After-sales Service: 1 year
Warranty: 1 year
Accuracy: ±0.2-0.5%
Main Application: Water, Wastewater, Diesel Fuel, Fuel Oil, Corrosive Liquid/Gas
Size: DN100-500
Sensor: Tube/Flange
Customization:

360° Virtual Tour

Diamond Member Since 2012

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
MFE600E
Application
Industrial Production
Type
Electromagnetic Flow Meter
Measuring Media
Liquid
Measuring Principle
Electrical Principles
Measurement Object
Closed Pipeline
Certification
ISO
Protection Class
IP65
Environment Temperature
-20c~60c
Output Signal
4-20madc
Alarm Output
Rated Value 30V DC, 100mA
Communication Signal
RS485 Communication Protocol
Load Resistance
250omega~ 600omega;
Diameter of Flowmeter
mm
Rated Voltage of Power Supply
220V AC: 100V~240V AC
Wire Terminals
M3 Screw
Housing Material
Aluminum Alloy
Transport Package
Standard Package for Exporting
Specification
ISO9000
Trademark
Micro Sensor
Origin
Baoji China

Product Description

Smart Integrated Flange Type Stable DN1400 Intelligent Electromagnetic Flow Meter MFE600E

Features:
 • The measurement accuracy will not be influenced by the fluid density, viscosity, temperature, pressure, and electrical conductivity changes;
• Open flow without moving parts in measuring pipe, no pressure loss;
• Simple structure, easy installation, no high requirements for straight pipe section;
• No mechanical inertia, with good sensitivity, it can measure the transient pulsating flux, and has good linearity;
• Only the lining and electrodes contact with the media, as long as the selection of electrode and lining materials is proper, they can be corrosion resistance and abrasive resistance, and are able to ensure long-term use;
• Multi-electrode structure ensures high accuracy. With the grounding electrode, it doesn't need a grounding ring which saves the cost;
• When power off, EEPROM can protect parameter setting and cumulative values;
• The converter uses a low-power consumption single-chip for processing data which ensure reliable performance, high accuracy, low power consumption, and zero stability. Dot-matrix LCD can display the integrated flux, transient flux, velocity, flow percentage, and other parameters;
• Two-way measuring system can be used for measuring forward flux and reverse flux; low-frequency rectangular wave excitation improves the stability of flow, low power loss, and superior low-velocity characteristic.
 
Introduction
MFE600E Series Electromagnetic Flowmeter (hereinafter called Electromagnetic Flowmeter) is designed and manufactured with the most advanced domestic and abroad technology, featuring high accuracy, reliability, good stability and long service life.

We pay attention to every detail in the process of the product structure design, material selection, manufacturing, assembly and factory testing, etc. With a water tower up to 37m as pressure stabilizer for actual flow calibration, we have a professional production line for electromagnetic flowmeter, also we design and develop a series of software and hardware for electromagnetic flowmeter for mass production to ensure high quality in long term use. The product has backlight and wide temperature-ranged LCD display. With fully practical function, visual display, easy operation, it saves troubles for on-site installation operation and maintenance. MFE600E can be widely used in industrial fields such as petroleum, chemical, metallurgy, water supply and drainage, steel, coal, paper, food, textile, environmental protection and other municipal administration, water conservancy construction field, etc.


Performance
 
Diameter Flange type: DN6~DN1600, ≥DN20 with built-in grounding electrode
Sanitary type: DN6~DN50
Threaded type: DN6~DN50
Clamping type: DN10~DN300
Measurement accuracy ±0.2%FS,±0.5%FS



Electrode type
Standard fixed electrode, antifouling electrode
DN6~DN20: a pair of measuring electrodes, no grounding electrodes
DN25~DN500: a pair of measuring electrodes and a pair of grounding electrodes
≥DN600: 2 pairs of measuring electrodes and a pair of grounding electrodes
Structure type Integrated type, separated type (cable length of separated type≤100m)




Rated pressure
GB: PN2.5, PN6, PN16, PN25, PN40, PN63, PN100, PN160, PN250
ANSI: CLASS 150, CLASS 300, CLASS 600, CLASS 900
DIN: PN10, PN16, PN25, PN40, PN63
JIS: 5K,10K,16K, 20K, 30K, 40K, 63K
Others: customizable
Electrode material 316L, Ti, HB/HC, Ta, WC, Pt

Lining material
Neoprene (CR), Natural Rubber (NR), Polyurethane Rubber (PU)
Polytetrafluoroethylene (PTFE), F46, PFA
Measured pipe Stainless steel
Flange/body flange Carbon steel (standard), stainless steel (optional)
Converter housing Aluminum die-casting




Power supply
100 V AC~240V AC
12V DC, 24V DC

Battery supply (LCD display, RS485 output, wireless output, frequency/pulse output, and the frequency/pulse output is used only for calibration or calibration purposes.)
Solar power with storage battery






Output signal
4mA~20mA DC (load resistance 0Ω~750Ω, active output)
Hart
Frequency, pulse output (Passive, active output optional)
Upper and lower limit alarm output
RS485 (standard Modbus protocol), RS232
Profibus-DP, Profibus-PA
2G, 4G, NB, LoRa wireless transmission
Electrical connection M20×1.5
IP protection IP65, IP68 (separated type only)
Environmental temp. -20ºC ~60ºC
Storage temp. -40ºC ~60ºC
Relative humidity 5%~90%


Table 2 Integrated flowmeter dimensions

DN
Rated Pressure

(MPa)
Outline Dimension(mm) Flange Connection Dimension(mm)
A H D K n-φL
6






4.0
150 304 90 60 4-Φ14
10 150 304 90 60 4-Φ14
15 150 304 95 65 4-Φ14
20 150 304 105 75 4-Φ14
25 150 312 115 85 4-Φ14
32 150 330 140 100 4-Φ18
40 150 340 150 110 4-Φ18
50 200 338 165 125 4-Φ18
65 200 358 185 145 8-Φ18
80 200 374 200 160 8-Φ18
100

1.6
250 402 220 180 8-Φ18
125 250 425 250 210 8-Φ18
150 300 458 285 240 8-Φ23
200







1.0
350 522 340 295 8-Φ23
250 400 574 395 350 12-Φ23
300 500 624 445 400 12-Φ23
350 500 678 500 460 16-Φ23
400 600 742 656 515 16-Φ25
450 600 794 615 565 20-Φ25
500 600 862 670 620 20-Φ25
600 600 950 780 725 20-Φ25
700 700 1058 895 840 24-Φ30
800 800 1166 1010 950 24-Φ34
900 900 1272 1110 1050 28-Φ34
1000 1000 1376 1220 1160 28-Φ34
1200

0.6
1200 1578 1405 1340 32-Φ34
1400 1400 1840 1630 1560 36-Φ36
1600 1600 2078 1830 1760 40-Φ36

Separated flowmeter dimensions:

DN
Rated Pressure

(MPa)
Outline Dimension(mm) Flange Connection Dimension(mm)
A H D K n-φL
6






4.0
150 245 Φ90 Φ60 4-Φ14
10 150 245 Φ90 Φ60 4-Φ14
15 150 245 Φ95 φ65 4-Φ14
20 150 245 Φ105 Φ75 4-Φ14
25 150 252 Φ115 ΦΦ85 4-Φ14
32 150 270 Φ140 100φ 4-Φ18
40 150 280 Φ150 Φ110 4-Φ18
50 200 280 Φ165 Φ125 4-Φ18
65 200 300 Φ185 Φ145 8-Φ18
80 200 314 Φ200 Φ160 8-Φ18
100

1.6
250 342 Φ220 Φ180 8-Φ18
125 250 366 Φ250 Φ210 8-Φ18
150 300 400 Φ285 Φ240 8-Φ23
200








1.0
350 464 Φ340 Φ295 8-Φ23
250 400 516 Φ395 Φ350 12-Φ23
300 500 566 Φ445 Φ400 12-Φ23
350 500 618 φ500 Φ460 16-Φ23
400 600 682 Φ656 Φ515 16-Φ25
450 600 734 Φ615 Φ565 20-Φ25
500 600 802 Φ670 Φ620 20-Φ25
600 600 892 Φ780 Φ725 20-Φ25
700 700 998 Φ895 Φ840 24-Φ30
800 800 1106 Φ1010 Φ950 24-Φ34
900 900 1212 Φ1110 Φ1050 28-Φ34
1000 1000 1316 Φ1220 Φ1160 28-Φ34
1200

0.6
1200 1518 Φ1405 Φ1340 32-Φ34
1400 1400 1780 Φ1630 Φ1560 36-Φ36
1600 1600 2018 Φ1830 Φ1760 40-Φ36


Sensor Grounding
Since the voltage of the inductive signal of the electromagnetic flowmeter is small, it is easily affected by noise. Its reference potential must be the same as the measured liquid potential. Therefore, the reference potential of the sensor (terminal potential), the reference potential of converters and amplifiers are also the same as measured liquid potential, and the liquid potential has to be the same as the ground potential. The electromagnetic flowmeter is equipped with a ground loop, which is for establishing a liquid ground via contact with liquid, and for protecting lining meanwhile. The instrument grounding is shown as below:
Smart Integrated Flange Type Stable DN1400 Intelligent Electromagnetic Flow Meter MFE600E
Order Notes

According to statistics from authoritative organizations in the world, one-third of the cases of flow meter failure are caused by the quality of the product itself, and two-thirds of the cases are caused by product selection and on-site installation that do not meet the requirements. The selection of an electromagnetic flowmeter requires the implementation of the following parameters.
1. Collect process data
a)The name of the measured fluid, and the composition of the chemical substance contained;
b)Max. flow, min. flow, common flow;
c)Max. Working pressure;
d)Max. Temp., min. Temp.

2. The measured fluid must be conductive, conductivity
> 5μS/cm.

3. The maximum flow and the minimum flow must conform to the values of the flow range in table 7.
4. When measuring cleaning media, the economic low rate is 1.5m/s~3m/s; When measuring easy crystallization solution, the flow rate should be appropriately increased to 3m/s~4m/s to automatically clean and prevent adhesion deposition; for measuring ore slurry, etc. For wear-resistant fluids, the flow rate should be appropriately reduced to 1m/s~2m/s to reduce the wear on the lining and electrodes. In practical applications, there is rarely a flow velocity exceeding 7m/s, and it is even rarer to exceed 10m/s.
5.The actual maximum working pressure must be less than the rated working pressure of the flowmeter.
6. The maximum and minimum working temperature must meet the requirements specified in the flowmeter.
7. Confirm whether there is negative pressure in process pipeline.

 
Certificates We Have
Smart Integrated Flange Type Stable DN1400 Intelligent Electromagnetic Flow Meter MFE600E
Company Overview
Smart Integrated Flange Type Stable DN1400 Intelligent Electromagnetic Flow Meter MFE600E
Products Family
Smart Integrated Flange Type Stable DN1400 Intelligent Electromagnetic Flow Meter MFE600E

Applications:
Smart Integrated Flange Type Stable DN1400 Intelligent Electromagnetic Flow Meter MFE600E
Exhibition:
Smart Integrated Flange Type Stable DN1400 Intelligent Electromagnetic Flow Meter MFE600E
FAQ:
1. Q: Are you a manufacturer or trading company?
    A: We are a 48-year professional manufacturer of Pressure/ Level/ Temperature/Flow transmitters with 4~20mA, Hart, Rs485 & Modbus protocols, pressure sensors with SDI, I2C, 4~20mA, 0.5~4.5V and etc, and wireless IOT measurement transmitters. We provide high-quality products with high competitive factory prices.
 
2. Q: What's your quality control system?
    A: As an ISO9001:2008 certificated manufacturer, we have a strict quality control system, and each product is done with fatigue testing, calibration, temperature compensation before shipment. High quality is guaranteed.
 
3Q: Is there MOQ with your product?
    A: We have no MOQ limits, 1pc for testing is acceptable.
 
4Q: Do you provide customized products?
    A: Yes, we can print your logo on our products; OEM, ODM & customization are welcomed.
 
5. Q: What is the warranty of your products? And after-sales service?
    A: Our warranty time is 12 months after shipment, and our after-sales will respond with your questions in 24hrs, remote instruction by PC network is always available.
 
6. Q: What is the lead time of your product?
    A: We are a factory, our lead time is always within 10~15 working days for products without customization, but lead-time will vary based on different products. You can check detailed lead-time with our sales.

7. Q: What international certificates do you have for your products?
    A: We have CE, RoHS, UL, ATEX as well as ship-use DNV, etc.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

360° Virtual Tour

Diamond Member Since 2012

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company
Year of Establishment
1993-03-18
Terms of Payment
T/T, PayPal