Customization: | Available |
---|---|
Accuracy: | ±0.2-0.5% |
Main Application: | Water, Wastewater, Diesel Fuel, Fuel Oil, Corrosive Liquid/Gas |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
MFE600 Intelligent Electromagnetic Flowmeter is designed and manufactured with the most advanced domestic and abroad technology, featuring high accuracy, reliability, good stability and long service life.
We pay our attention to every detail in the process of the product structure design, material selection, manufacturing, assembly and factory testing etc. With a water tower up to 35m as pressure stabilizer for actual flow calibration, we have a professional production line for electromagnetic flowmeter, also we design and develop a series of software and hardware for electromagnetic flowmeter for mass production to ensure high quality in long term use. The product has backlight and wide temperature-ranged Chinese LCD display. With fully practical function, visual display, easy operation, it saves troubles for on-site installation operation and maintenance. MFE600 can be widely used in industrial fields such as petroleum, chemical, metallurgy, water supply and drainage, steel, coal, paper, food, textile, environmental protection and other municipal administration, water conservancy construction field etc.
Input signal: signal emitted from the sensor directly proportional to the flow.
Output signal: 4mA ~ 20mA DC (load resistance 0Ω ~ 750Ω).
Select pulse / alarm output by parameter setup
Pulse output: (pulled up resistor already)
4mA ~ 20mA DC Output: Current output is active output.
Alarm output: rated value 30V DC, 100mA
Communication signal: RS485 communication protocol (optional);
RS232 communication protocol (optional)
Load Resistance: 250Ω ~ 600Ω (including cable resistance)
Load Capacitance: 0.22μF (Max)
Load inductance: 3.3mH (Max)
Space between split cables: ≤100m
Input impedance of receiving instrument: ≥10kΩ (@ 2.4kHz)
Diameter | DN10 ~ DN800 |
Excitation type Mode | Constant flux square wave excitation Installation form: an integral flange, split flange Lined :neoprene, urethane rubber, PTFE, F46 Electrode materials: 316L, Hc, Hb, titanium, tantalum, platinum iridium, tungsten carbide
Ground :built-in ground electrode (DN25 and above)
Media: Conductive liquidAccuracy grade: 0.2,0.5,1.0 Medium conductivity> 5 μS / cm Flow velocity ≤ 15 m / s Pipe connected Flange GB 81 ~ 59 Pipe connection: flange connection |
Installation | Integrated flanged, Separated Flanged |
Lining | Neoprene, Polyurethane rubber, PTFE,F46 |
Electrode Material |
316L, Hc, Hb, Titanium, Tantalum, Platinum iridium, Tungsten carbide |
Grounding | Built-in grounding electrode (DN25 and above) |
Medium | Conductive liquid |
Accuracy Grade | 0.2, 0.5, 1.0 |
Media Conductivity | > 5 μS/cm |
Velocity | ≤ 15 m/s |
Pipe Connection Flange | Flange GB 81~59 |
Pipe Connection | Flange Connection |
Media Temp. | Neoprene: -10ºC~ 60ºC; PTFE: -10ºC~ 120ºC Urethane Rubber: -10ºC~80ºC; F46: -10ºC~ 150ºC |
Rated Pressure | 4.0 MPa; 1.6 MPa; 1.0 MPa |
Protection Level | IP65; IP68 |
Output signal | 4mA~ 20mA DC current; Pulse/ Frequency, Alarm after Upper and Lower limits |
Cable connection | M20×1.5 female |
Communication | RS 485 protocol (Modbus protocol) RS 232 protocol (optional) |
Display | Transient flux, Alarm display, Percentage, Velocity, Forward and Reverse Integrated Flux and Total Integrated Flux |
Power supply | 220V AC,24V DC,3.6 V battery power supply |
Type | General, Waterproof |
High Voltage | Customized |
Diameter | DN10 ~ DN500 | |
Excitation type Mode | Constant flux square wave excitation Installation form: an integral flange, split flange Lined :neoprene, urethane rubber, PTFE, F46 Electrode materials: 316L, Hc, Hb, titanium, tantalum, platinum iridium, tungsten carbide Ground :built-in ground electrode (DN25 and above) Media: Conductive liquid Accuracy grade: 0.2,0.5,1.0 Medium conductivity> 5 μS / cm Flow velocity ≤ 15 m / s Pipe connected Flange GB 81 ~ 59 Pipe connection: flange connection |
|
Installation | Integrated clamp-on, Separated clamp-on | |
Lining | Neoprene, Polyurethane rubber, PTFE,F46 | |
Electrode Material |
316L, Hc, Hb, Titanium, Tantalum, Platinum iridium, Tungsten carbide | |
Grounding | Built-in grounding electrode (DN25 and above) | |
Medium | Conductive liquid | |
Accuracy Grade | 0.2, 0.5, 1.0 | |
Media Conductivity | > 5μS/cm | |
Velocity | ≤ 15 m/s | |
Pipe Connection Flange | Flange GB 81~59 | |
Pipe Connection | Flange Connection | |
Media Temp. | Neoprene: -10ºC~ 60ºC; PTFE: -10ºC ~ 120ºC Urethane Rubber: -10ºC~80ºC; F46: -10ºC~ 150ºC |
|
Rated Pressure | 4.0 MPa; 1.6 MPa; 1.0MPa | |
Protection Level | IP65; IP68 | |
Output signal | 4mA~ 20mA DC current; Pulse/ Frequency, Alarm after Upper and Lower limits | |
Cable connection | M20×1.5 female | |
Communication | RS 485 protocol(modbus protocol) RS 232 protocol(optional) |
|
Display | Transient flux, Alarm display, Percentage, Velocity, Forward and Reverse Integrated Flux and Total Integrated Flux | |
Power supply | 220V AC,24V DC,3.6V battery power supply | |
Type | General, Waterproof | |
High Voltage | Customized |