Basic Info.
After-sales Service
1 year
Main Application
Water, Wastewater, Diesel Fuel, Fuel Oil, Corrosive Liquid/Gas
Type
Electromagnetic Flow Meter
Environment Temperature
-20c~60c
Alarm Output
Rated Value 30V DC, 100mA
Communication Signal
RS485 Communication Protocol
Load Resistance
250omega~ 600omega;
Rated Voltage of Power Supply
220V AC: 100V~240V AC
Housing Material
Aluminum Alloy
Product Description
Flange Type Integrated Type DN500 Electromagnetic Flow Meter MFE600E
Features:
• The measurement accuracy will not be influenced by the fluid density, viscosity, temperature, pressure, and electrical conductivity changes;
• Open flow without moving parts in measuring pipe, no pressure loss;
• Simple structure, easy installation, no high requirements for straight pipe section;
• No mechanical inertia, with good sensitivity, it can measure the transient pulsating flux, and has good linearity;
• Only the lining and electrodes contact with the media, as long as the selection of electrode and lining materials is proper, they can be corrosion resistance and abrasive resistance, and are able to ensure long-term use;
• Multi-electrode structure ensures high accuracy. With the grounding electrode, it doesn't need a grounding ring which saves the cost;
• When power off, EEPROM can protect parameter setting and cumulative values;
• The converter uses a low-power consumption single-chip for processing data which ensure reliable performance, high accuracy, low power consumption, and zero stability. Dot-matrix LCD can display the integrated flux, transient flux, velocity, flow percentage, and other parameters;
• Two-way measuring system can be used for measuring forward flux and reverse flux; low-frequency rectangular wave excitation improves the stability of flow, low power loss, and superior low-velocity characteristic.
Introduction
MFE600E Series Electromagnetic Flowmeter (hereinafter called Electromagnetic Flowmeter) is designed and manufactured with the most advanced domestic and abroad technology, featuring high accuracy, reliability, good stability and long service life.
We pay attention to every detail in the process of the product structure design, material selection, manufacturing, assembly and factory testing, etc. With a water tower up to 37m as pressure stabilizer for actual flow calibration, we have a professional production line for electromagnetic flowmeter, also we design and develop a series of software and hardware for electromagnetic flowmeter for mass production to ensure high quality in long term use. The product has backlight and wide temperature-ranged LCD display. With fully practical function, visual display, easy operation, it saves troubles for on-site installation operation and maintenance. MFE600E can be widely used in industrial fields such as petroleum, chemical, metallurgy, water supply and drainage, steel, coal, paper, food, textile, environmental protection and other municipal administration, water conservancy construction field, etc.
Performance
Diameter | Flange type: DN6~DN1600, ≥DN20 with built-in grounding electrode |
Sanitary type: DN6~DN50 |
Threaded type: DN6~DN50 |
Clamping type: DN10~DN300 |
Measurement accuracy | ±0.2%FS,±0.5%FS |
Electrode type | Standard fixed electrode, antifouling electrode |
DN6~DN20: a pair of measuring electrodes, no grounding electrodes |
DN25~DN500: a pair of measuring electrodes and a pair of grounding electrodes |
≥DN600: 2 pairs of measuring electrodes and a pair of grounding electrodes |
Structure type | Integrated type, separated type (cable length of separated type≤100m) |
Rated pressure | GB: PN2.5, PN6, PN16, PN25, PN40, PN63, PN100, PN160, PN250 |
ANSI: CLASS 150, CLASS 300, CLASS 600, CLASS 900 |
DIN: PN10, PN16, PN25, PN40, PN63 |
JIS: 5K,10K,16K, 20K, 30K, 40K, 63K |
Others: customizable |
Electrode material | 316L, Ti, HB/HC, Ta, WC, Pt |
Lining material | Neoprene (CR), Natural Rubber (NR), Polyurethane Rubber (PU) |
Polytetrafluoroethylene (PTFE), F46, PFA |
Measured pipe | Stainless steel |
Flange/body flange | Carbon steel (standard), stainless steel (optional) |
Converter housing | Aluminum die-casting |
Power supply | 100 V AC~240V AC |
12V DC, 24V DC |
Battery supply (LCD display, RS485 output, wireless output, frequency/pulse output, and the frequency/pulse output is used only for calibration or calibration purposes.) |
Solar power with storage battery |
Output signal | 4mA~20mA DC (load resistance 0Ω~750Ω, active output) |
Hart |
Frequency, pulse output (Passive, active output optional) |
Upper and lower limit alarm output |
RS485 (standard Modbus protocol), RS232 |
Profibus-DP, Profibus-PA |
2G, 4G, NB, LoRa wireless transmission |
Electrical connection | M20×1.5 |
IP protection | IP65, IP68 (separated type only) |
Environmental temp. | -20ºC ~60ºC |
Storage temp. | -40ºC ~60ºC |
Relative humidity | 5%~90% |
Table 2 Integrated flowmeter dimensionsDN | Rated Pressure
(MPa) | Outline Dimension(mm) | Flange Connection Dimension(mm) |
A | H | D | K | n-φL |
6 |
4.0 | 150 | 304 | 90 | 60 | 4-Φ14 |
10 | 150 | 304 | 90 | 60 | 4-Φ14 |
15 | 150 | 304 | 95 | 65 | 4-Φ14 |
20 | 150 | 304 | 105 | 75 | 4-Φ14 |
25 | 150 | 312 | 115 | 85 | 4-Φ14 |
32 | 150 | 330 | 140 | 100 | 4-Φ18 |
40 | 150 | 340 | 150 | 110 | 4-Φ18 |
50 | 200 | 338 | 165 | 125 | 4-Φ18 |
65 | 200 | 358 | 185 | 145 | 8-Φ18 |
80 | 200 | 374 | 200 | 160 | 8-Φ18 |
100 | 1.6 | 250 | 402 | 220 | 180 | 8-Φ18 |
125 | 250 | 425 | 250 | 210 | 8-Φ18 |
150 | 300 | 458 | 285 | 240 | 8-Φ23 |
200 |
1.0 | 350 | 522 | 340 | 295 | 8-Φ23 |
250 | 400 | 574 | 395 | 350 | 12-Φ23 |
300 | 500 | 624 | 445 | 400 | 12-Φ23 |
350 | 500 | 678 | 500 | 460 | 16-Φ23 |
400 | 600 | 742 | 656 | 515 | 16-Φ25 |
450 | 600 | 794 | 615 | 565 | 20-Φ25 |
500 | 600 | 862 | 670 | 620 | 20-Φ25 |
600 | 600 | 950 | 780 | 725 | 20-Φ25 |
700 | 700 | 1058 | 895 | 840 | 24-Φ30 |
800 | 800 | 1166 | 1010 | 950 | 24-Φ34 |
900 | 900 | 1272 | 1110 | 1050 | 28-Φ34 |
1000 | 1000 | 1376 | 1220 | 1160 | 28-Φ34 |
1200 | 0.6 | 1200 | 1578 | 1405 | 1340 | 32-Φ34 |
1400 | 1400 | 1840 | 1630 | 1560 | 36-Φ36 |
1600 | 1600 | 2078 | 1830 | 1760 | 40-Φ36 |
Separated flowmeter dimensions:DN | Rated Pressure
(MPa) | Outline Dimension(mm) | Flange Connection Dimension(mm) |
A | H | D | K | n-φL |
6 |
4.0 | 150 | 245 | Φ90 | Φ60 | 4-Φ14 |
10 | 150 | 245 | Φ90 | Φ60 | 4-Φ14 |
15 | 150 | 245 | Φ95 | φ65 | 4-Φ14 |
20 | 150 | 245 | Φ105 | Φ75 | 4-Φ14 |
25 | 150 | 252 | Φ115 | ΦΦ85 | 4-Φ14 |
32 | 150 | 270 | Φ140 | 100φ | 4-Φ18 |
40 | 150 | 280 | Φ150 | Φ110 | 4-Φ18 |
50 | 200 | 280 | Φ165 | Φ125 | 4-Φ18 |
65 | 200 | 300 | Φ185 | Φ145 | 8-Φ18 |
80 | 200 | 314 | Φ200 | Φ160 | 8-Φ18 |
100 | 1.6 | 250 | 342 | Φ220 | Φ180 | 8-Φ18 |
125 | 250 | 366 | Φ250 | Φ210 | 8-Φ18 |
150 | 300 | 400 | Φ285 | Φ240 | 8-Φ23 |
200 |
1.0 | 350 | 464 | Φ340 | Φ295 | 8-Φ23 |
250 | 400 | 516 | Φ395 | Φ350 | 12-Φ23 |
300 | 500 | 566 | Φ445 | Φ400 | 12-Φ23 |
350 | 500 | 618 | φ500 | Φ460 | 16-Φ23 |
400 | 600 | 682 | Φ656 | Φ515 | 16-Φ25 |
450 | 600 | 734 | Φ615 | Φ565 | 20-Φ25 |
500 | 600 | 802 | Φ670 | Φ620 | 20-Φ25 |
600 | 600 | 892 | Φ780 | Φ725 | 20-Φ25 |
700 | 700 | 998 | Φ895 | Φ840 | 24-Φ30 |
800 | 800 | 1106 | Φ1010 | Φ950 | 24-Φ34 |
900 | 900 | 1212 | Φ1110 | Φ1050 | 28-Φ34 |
1000 | 1000 | 1316 | Φ1220 | Φ1160 | 28-Φ34 |
1200 | 0.6 | 1200 | 1518 | Φ1405 | Φ1340 | 32-Φ34 |
1400 | 1400 | 1780 | Φ1630 | Φ1560 | 36-Φ36 |
1600 | 1600 | 2018 | Φ1830 | Φ1760 | 40-Φ36 |
Sensor Grounding
Since the voltage of the inductive signal of the electromagnetic flowmeter is small, it is easily affected by noise. Its reference potential must be the same as the measured liquid potential. Therefore, the reference potential of the sensor (terminal potential), the reference potential of converters and amplifiers are also the same as measured liquid potential, and the liquid potential has to be the same as the ground potential. The electromagnetic flowmeter is equipped with a ground loop, which is for establishing a liquid ground via contact with liquid, and for protecting lining meanwhile. The instrument grounding is shown as below:
Order Notes
According to statistics from authoritative organizations in the world, one-third of the cases of flow meter failure are caused by the quality of the product itself, and two-thirds of the cases are caused by product selection and on-site installation that do not meet the requirements. The selection of an electromagnetic flowmeter requires the implementation of the following parameters.
1. Collect process data
a)The name of the measured fluid, and the composition of the chemical substance contained;
b)Max. flow, min. flow, common flow;
c)Max. Working pressure;
d)Max. Temp., min. Temp.
2. The measured fluid must be conductive, conductivity
> 5μS/cm.
3. The maximum flow and the minimum flow must conform to the values of the flow range in table 7.
4. When measuring cleaning media, the economic low rate is 1.5m/s~3m/s; When measuring easy crystallization solution, the flow rate should be appropriately increased to 3m/s~4m/s to automatically clean and prevent adhesion deposition; for measuring ore slurry, etc. For wear-resistant fluids, the flow rate should be appropriately reduced to 1m/s~2m/s to reduce the wear on the lining and electrodes. In practical applications, there is rarely a flow velocity exceeding 7m/s, and it is even rarer to exceed 10m/s.
5.The actual maximum working pressure must be less than the rated working pressure of the flowmeter.
6. The maximum and minimum working temperature must meet the requirements specified in the flowmeter.
7. Confirm whether there is negative pressure in process pipeline.
Certificates We Have
Company Overview
Products Family
Applications:
Exhibition:
FAQ:
1. Q: Are you a manufacturer or trading company?
A: We are a 48-year professional manufacturer of Pressure/ Level/ Temperature/Flow transmitters with 4~20mA, Hart, Rs485 & Modbus protocols, pressure sensors with SDI, I2C, 4~20mA, 0.5~4.5V and etc, and wireless IOT measurement transmitters. We provide high-quality products with high competitive factory prices.
2. Q: What's your quality control system?
A: As an ISO9001:2008 certificated manufacturer, we have a strict quality control system, and each product is done with fatigue testing, calibration, temperature compensation before shipment. High quality is guaranteed.
3. Q: Is there MOQ with your product?
A: We have no MOQ limits, 1pc for testing is acceptable.
4. Q: Do you provide customized products?
A: Yes, we can print your logo on our products; OEM, ODM & customization are welcomed.
5. Q: What is the warranty of your products? And after-sales service?
A: Our warranty time is 12 months after shipment, and our after-sales will respond with your questions in 24hrs, remote instruction by PC network is always available.
6. Q: What is the lead time of your product?
A: We are a factory, our lead time is always within 10~15 working days for products without customization, but lead-time will vary based on different products. You can check detailed lead-time with our sales.
7. Q: What international certificates do you have for your products?
A: We have CE, RoHS, UL, ATEX as well as ship-use DNV, etc.
Address:
No. 18 Yingda Road, Baoji, Shaanxi, China
Business Type:
Manufacturer/Factory
Business Range:
Agriculture & Food, Chemicals, Electrical & Electronics, Health & Medicine, Industrial Equipment & Components, Instruments & Meters, Light Industry & Daily Use, Manufacturing & Processing Machinery, Metallurgy, Mineral & Energy, Service
Management System Certification:
ISO 9001, ISO 14001, OHSAS/ OHSMS 18001
Company Introduction:
Since its inception in 1993, Micro Sensor Co., Ltd. (referred to as "Micro Sensor") has been a global industrial instrumentation manufacturer. Specializing in providing industrial measuring instrument solutions for pressure, level, temperature, and flow, Micro Sensor serves various industries including oil & gas, renewable energy, industrial gases, water & wastewater, marine & shipbuilding, HVAC, hydraulics & pneumatics, mechanical manufacturing & automation, as well as food & beverage and paper.
Micro Sensor boasts a global workforce of over 800 employees and operates four industrial parks in three locations in China (Baoji, Xi′an, and Shanghai), with the additional establishment of Micro Sensor GmbH in Essen, Germany. The company′s technical R&D is based on the "IPD R&D management system, " with over 100 core R&D experts and more than 140 R&D patents, as well as over 220 domestic and international certificates. It serves customers in over 100 countries and regions, accumulating to over 20, 000 satisfied clients.
Micro Sensor employs the "IPD R&D management system" in the term of technological R&D. It has established industry-leading high-standard laboratories in Baoji, Xi′an, and Shanghai, with over 100 core R&D experts and more than 140 R&D patents. The company has obtained over 220 domestic and international professional certificates, including CE, RoHS, UL, CB, Ex, 3A, ATEX, CCS, MA, DNV· GL, and SON, and has contributed to the development of a total of 9 national, regional, and industry standards. Additionally, the company holds numerous qualification certificates, such as ICE Systems Certificate, ATEX Explosion-Proof Quality Management Systems Certificate, ISO 14001: 2015 Environmental Management Systems Certificate, ISO 45001: 2018 Occupational Health and Safety Management Systems Certificate, and ISO 9001: 2015 Quality Management Systems Certificate, etc.