Micro Sensor HART and RS485 Digital Signal FlowMeters MFE600C Insert Type Electromagnetic Water Flow Meters

Product Details
Customization: Available
After-sales Service: 1 year
Warranty: 1 year
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2012

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Year of Establishment
1993-03-18
Terms of Payment
T/T, PayPal
  • Micro Sensor HART and RS485 Digital Signal FlowMeters MFE600C Insert Type Electromagnetic Water Flow Meters
  • Micro Sensor HART and RS485 Digital Signal FlowMeters MFE600C Insert Type Electromagnetic Water Flow Meters
  • Micro Sensor HART and RS485 Digital Signal FlowMeters MFE600C Insert Type Electromagnetic Water Flow Meters
Find Similar Products

Basic Info.

Model NO.
MFE600C
Main Application
Water, Wastewater, Diesel Fuel, Fuel Oil, Corrosive Liquid/Gas
Size
DN200~1600
Sensor
Tube/Flange
Application
Industrial Production
Type
Electromagnetic Flow Meter
Measuring Media
Liquid
Measuring Principle
Electrical Principles
Measurement Object
Closed Pipeline
Certification
ISO
Protection Class
IP65
Environment Temperature
-20c~60c
Output Signal
4-20madc
Alarm Output
Rated Value 30V DC, 100mA
Communication Signal
RS485 Communication Protocol
Load Resistance
250omega~ 600omega;
Diameter of Flowmeter
mm
Rated Voltage of Power Supply
220V AC: 100V~240V AC
Wire Terminals
M3 Screw
Housing Material
Aluminum Alloy
Transport Package
Standard Package for Exporting
Specification
ISO9000
Trademark
Micro Sensor
Origin
Baoji China
Production Capacity
100000

Product Description

24VDC Powered Wasted Water Treatment Sewage Customized Electromagnetic Flow Meter MFE600C

Features: 
• The special structure of the insert flowmeter can be easily installed and disassembled under the condition of low pressure and non-stop water. Therefore, it is very suitable for fluid measurement of existing pipelines and facilitates the maintenance and repair of instruments;
• Adopt advanced low frequency square wave excitation. The zero point is stable, the anti-interference ability is strong, and the work is reliable;
• Compared with the general electromagnetic flowmeter, the manufacturing cost and installation cost are lower;
• Two-way measurement system can measure forward flow and reverse flow; low frequency rectangular wave excitation improves flow stability, low power loss, and excellent low flow rate characteristics.

 
Introduction
MFE600C Insert electromagnetic flowmeter is a new type of flow measuring instrument developed on the basis of pipeline electromagnetic flowmeter. On the basis of retaining the advantages of the pipeline electromagnetic flowmeter, the defects of difficult installation and high cost of the pipeline electromagnetic flowmeter on large pipelines are avoided. In particular, the method of opening under pressure and installation under pressure can be adopted, so that the plug-in flowmeter can be constructed and installed without stopping the water. It provides a new method for the measurement and installation of liquid flow. At present, it has been widely used in chemical industry, water supply and drainage, sewage treatment and other industries.

Working Principle
The working principle of Electromagnetic Flowmeter is based on Faraday's Law of Electromagnetic Induction, that is, when the conductive liquid flows through the electromagnetic flowmeter, the induced electromotive force will be produced in the liquid conductor, and the induced electromotive force is directly proportional to the velocity of conductive liquid, magnetic flux density and width of conductor (interior diameter of flowmeter). Such induced electromotive force is detected by a pair of electrodes on the tube wall of the flowmeter, and the equation of induced electromotive force is as follows: U = K×B×V×D U: Induced electromotive force K: Instrument Constant B: Magnetic flux density V: Velocity D: Interior diameter of measuring pipe

Measurement Range setting
The volumetric flux is set by the setup of volume unit, flux value and diameter of flowmeter. 
Volume unit: M3
Velocity unit: M/s
Diameter of flowmeter: mm
Transient flux display: Display flux unit, and the percentage of range. 
Integrated flux display: Display forward and reverse integrated flux and total integrated flux. 
Pulse output: By setting an impulse ratio, the pulse quantity expressed in any flux unit can be output. 
Pulse width: Duty ratio of 50% or fixed pulse width is available for users to choose. 
Output speed: 10 to 400 (PPS) (only applicable when the form of pulse output is selected). 
Black-out data protection: Data will be stored by EEPROM without backup battery. 
Forward and Reverse flux measurement: In the model of forward and reverse flow direction, the reverse flux can be measured. 
Upper limit alarm: The transient flux is larger than the upper limit of setting value
Lower limit alarm: The transient flux is smaller than the lower limit of setting value
Damping function: Available to set from 0.2s ~ 100s (63% response time)

Normal Working Condition
Environment Temperature: -20ºC~60ºC
Rated Voltage of Power Supply: 
220V AC: 100V~240V AC
DC: 12V DC 24V DC

Installation and Structure
Installation: 

Separate model: Converter, 50mm pipe or plane installation
Integrated model: Combined with the sensor
Wire connector: ISO M20 × 1.5
Housing material: Aluminum alloy

Structure: 
Protection class: IP65 (general type); IP68 (waterproof)

 

MFE600C Electromagnetic Flowmeter Performance
Diameter DN150 ~ DN1600
Output signal 4mA~20mA DC (4mA to 0m³; 20mA to full scale) load resistance 0Ω~750Ω, active output Hart,RS485 ( Modbus protocol); Hart and RS485/ RS232 outputs cannot exist at the same time Profibus-DP 4G wireless transmission
Battery supply 3.6V, RS485 output, wireless output, frequency/ pulse output, and the frequency/pulse output is used only for calibration purposes
Medium Conductive liquid
Rated Pressure 4.0 MPa; 1.6 MPa; 1.0MPa
Protection Level IP65; IP67; IP68 (sensor part only)
Electrical connection ISO M20×1.5
Display Transient flux, Alarm display, Percentage, Velocity, Forward and Reverse Integrated Flux and Total Integrated Flux
Power supply 100V ~ 240V AC 12V DC, 24V DC
Type General, Waterproof
High Voltage Customized

Model Selection
The flowmeter model selection is very important in application of instrument. The related information shows that in practical application of instrument, 2/3 failures are caused by incorrect selection of model and incorrect installation of instrument to which the special attention shall be paid. 
1. Technological data collection
A. The measured fluid name and its chemical substances
B. Maximum flux, minimum flux and normal flux
C. Maximum working pressure; 
D. Maximum temperature, minimum temperature. 
2. The measured liquid shall have certain conductivity, electrical conductivity ≥5μS/cm. 
3. The maximum flux and the minimum flux shall meet the values in the measurable flux range table. 
4. The actual maximum working pressure shall be less than the rated working pressure of flowmeter. 
5. The maximum working temperature and the minimum working temperature shall meet the temperature requirements stipulated for flowmeter. 
6. Whether negative pressure exists or not in the processing pipeline shall be confirmed. 
You can also select the appropriate flowmeter electromagnetic flowmeter according to actual use, and if the interior diameter of the electromagnetic flowmeter selected differs from that of the existing process pipe, then pipe reduction or expansion shall be considered. 
1. If the pipeline should be contracted, whether the pressure loss caused by the pipe contraction will affect the process flow or not shall be considered. 
2. Considering the measurement accuracy and price, you can choose a smaller diameter electromagnetic flowmeter, which can reduce the investment relatively. 
3. When measuring clean water, the economic velocity is 2m/s ~3m/s; When measuring the solution of crystallization, the velocity shall be increased approximately to common velocity of ≥2 m/s, in order to prevent the electrode of electromagnetic from flowmeter being covered. 


Certificates We Have
Micro Sensor HART and RS485 Digital Signal FlowMeters MFE600C Insert Type Electromagnetic Water Flow Meters
Company Overview
Micro Sensor HART and RS485 Digital Signal FlowMeters MFE600C Insert Type Electromagnetic Water Flow Meters
Products Family
Micro Sensor HART and RS485 Digital Signal FlowMeters MFE600C Insert Type Electromagnetic Water Flow Meters

Applications:
Micro Sensor HART and RS485 Digital Signal FlowMeters MFE600C Insert Type Electromagnetic Water Flow Meters
FAQ:
1. Q: Are you a manufacturer or trading company?
    A: We are a 48-year professional manufacturer of Pressure/ Level/ Temperature/Flow transmitters with 4~20mA, Hart, Rs485 & Modbus protocols, pressure sensors with SDI, I2C, 4~20mA, 0.5~4.5V and etc, and wireless IOT measurement transmitters. We provide high-quality products with high competitive factory prices.
 
2. Q: What's your quality control system?
    A: As an ISO9001:2008 certificated manufacturer, we have a strict quality control system, and each product is done with fatigue testing, calibration, temperature compensation before shipment. High quality is guaranteed.
 
3Q: Is there MOQ with your product?
    A: We have no MOQ limits, 1pc for testing is acceptable.
 
4Q: Do you provide customized products?
    A: Yes, we can print your logo on our products; OEM, ODM & customization are welcomed.
 
5. Q: What is the warranty of your products? And after-sales service?
    A: Our warranty time is 12 months after shipment, and our after-sales will respond with your questions in 24hrs, remote instruction by PC network is always available.
 
6. Q: What is the lead time of your product?
    A: We are a factory, our lead time is always within 10~15 working days for products without customization, but lead-time will vary based on different products. You can check detailed lead-time with our sales.

7. Q: What international certificates do you have for your products?
    A: We have CE, RoHS, UL, ATEX as well as ship-use DNV, etc.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now