Customization: | Available |
---|---|
Type: | Silicon Piezoresistive Type |
Structure Design: | Input Type |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
·Water-proof connection box is recommended; install it in a place easy for electric connection; protection class IP65;
·Removable top Nylon cap; prevent diaphragm damage and ease cleaning;
·Compact size:Φ22 diameter
Pressure Range |
1m, 2m, 5m, 7m H2O |
|
Overpressure |
1.5 times FS |
|
Accuracy |
±1%FS |
|
Stability error |
±0.5% FS/ year |
|
Transmitting |
2-wire |
3-wire |
Power Supply |
11V~28V DC |
11V~28V DC |
Output Signal |
4mA~20mA DC |
0.5V~4.5V DC |
Load (Ω) |
< (U-11)/0.02 |
> 100k |
Material contacting with media |
Housing: stainless steel 304 |
Seal parts: Viton |
Diaphragm: SS 316L |
Cable: Φ7.5mm PUR cable with vent tube |
|
Cap: Nylon |
Rubber casing: Chloroprene Rubber |
|
Operation temp. |
-20ºC~60ºC |
|
Compensated Temp. |
0ºC~50ºC |
|
Storage Temp. |
-20ºC~70ºC |
|
Protection |
IP68 (sensor part) IP65 (connection box) |
Wire Color |
2-wire |
3-wire |
Black |
+V |
+V |
Red |
+OUT |
+OUT |
White |
Null |
GND |
Blue(Only with temperature signal) |
Null |
TEMP(+) |
Brown(Only with temperature signal) |
Null |
TEMP(+) |
Green(Only with temperature signal) |
Null |
DRAIN |
MPM489WZ3 |
Submersible Level Transmitter |
|
|||||||||||
|
|
Range |
1m, 2m, 5m, 7m H2O |
|
|||||||||
|
[0~XmH2O]L |
X: actual measured range L: cable length; suggested L-X=(1~2)m |
|
||||||||||
|
|
Code |
Output Signal |
|
|||||||||
E |
4mA~20mA DC |
|
|||||||||||
K |
0.5V~4.5V DC |
|
|||||||||||
|
|
Code |
Construction Material |
|
|||||||||
Diaphragm |
Pressure port |
Housing |
|
||||||||||
22 |
SS 316L |
SS |
SS |
|
|||||||||
24 |
SS 316L |
SS 316L |
SS 316L |
|
|||||||||
|
|
Code |
others |
|
|||||||||
|
M1 |
0%~100% hand pointer indicator(Current output only) |
|
||||||||||
|
Yb |
Aluminum connection box without display (Current output only) |
|
||||||||||
Yc |
MS200 water-proof connection box(Current output only) |
|
|||||||||||
Yd |
PD140 lightening-proof protection device (Current output only) |
|
|||||||||||
Ye |
connection box(with display or without display) (Current output only) |
|
|||||||||||
F1 |
Fixed flange |
|
|||||||||||
|
|
T |
With temperature sensor(Voltage output signal only) |
|
|||||||||
|
|
|
|||||||||||
MPM489WZ3 [0~3mH2O]5 E 22 Yc the whole spec. |
|
Certificates We Have