Customization: | Available |
---|---|
Type: | Medium & High Temperature Pressure Transmitter |
Structure Type: | Diffused Silicon Pressure Transmitter |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Gauge Digital Intelligent Display Transmission Air Control Pressure Transmitting Controller
Features
1. Real-time pressure display in unit: Bar or MPa
2. 14-segment LED display
3. Max. 5 relays control independently, time-delay function
4. Switchable analog output
5. Support back, rail, cover and joint mounting
6. Hardware wrong operation protection
7. Intrinsically safe products
8. Modbus communication
Specification:
Input
Power Supply: Non Intrinsically Safe: (220±44)V AC/22V~32V DC;
Intrinsically Safe: 22V~28V DC (Supplied by Safety Barrier)
Range: 0kPa~10kPa... 60MPa (MPM4881);
Over Pressure: 1.5FS
Output
Accuracy: ≤±0.25%FS;≤±0.5%FS; Repeatability: ≤±0.2%FS;
Display: 4 digit 0.56 inch 14-segment LED display; Temperature Drift: ≤±0.03%FS/ºC(zero/span);
Display Refresh: 200ms.
Analog Output
Current Version: 4mA~20mA DC, Load resistance ≤560Ω;
Voltage Version: 0V~10V DC, Load resistance ≥10kΩ.
Switch Output
Output Mode: 5 relays, normally open or close contact; Voltage Supply: ≤277V AC;≤30V DC;
Current Supply: ≤3A; Response: < 1ms;
Switch Point Setting: 1.5%FS~99%FS; Return Difference Setting: 1%FS~10%FS;
Relay Life: ≥10,000,000times/load (min.);≥100,000times/load (max.); Switch Delay: 0s~99s.
Environmental Conditions
Operation Temperature: -25ºC~65ºC/-13ºF~149ºF; Relative Humility: 0%~85%;
Storage Temperature: -40ºC~70ºC/-40ºF~158ºF; Media Temperature: -20ºC~80ºC/-50ºF~176ºF;
Electromagnetic compatibility: GB/T 17626.2/3/4-2006;
Outline Construction:
Order Guide:
MPM4881/ MDM4881 |
Pressure / Differential Pressure Transmitting Controller |
||||
|
Range |
0kPa~10kPa... 60MPa (pressure type) 0kPa~35kPa... 3.5MPa (differential pressure) |
|||
[0~X]kPa or MPa |
X: Actual Range |
||||
|
Code |
Power Supply |
|||
AC |
220V AC (Non Intrinsically Safe Only) |
||||
DC |
22V~32V DC (Non Intrinsically Safe); 22V~28V DC (Intrinsically Safe,supplied by Safety Barrier) |
||||
|
Code |
Output |
|||
KA |
5-relay +analog (4mA~20mA) |
||||
KV |
5-relay +analog (0V~10V) |
||||
KAV |
5-relay +analog (4mA~20mA / 0V~10V double use) |
||||
|
Code |
Process connection |
|||
C1 |
M20×1.5 male, face type seal |
||||
C3 |
G1/2 male |
||||
C4 |
G1/4female |
||||
C5 |
M20×1.5 male, waterline seal |
||||
i |
Intrinsically Safe ExibIIAT6 Gb |
||||
G |
Gauge |
||||
A |
Absolute |
||||
S |
Sealed Gauge |
||||
MPM4881/ MDM4881 |
[0~2]MPa |
DC |
KA |
C5G |
the whole spec. |
Notes
1. Process connection thread can be customized for users. Please specify it in the contract.
2. If the user has special requirement, please feel free to contact us.